ModEnc is currently in Maintenance Mode: Changes could occur at any given moment, without advance warning.

Difference between revisions of "SensorArray"

From ModEnc
Jump to: navigation, search
(Testing...)
m (Replacing Template:TTL with Template:F.)
Line 14: Line 14:
 
==In Tiberian Sun==
 
==In Tiberian Sun==
  
This flag determines whether or not a [[BuildingType]] can detect and reveal [[Cloakable|cloaked]] and [[subterranean]] units within a radius in cells specified by {{TTL|CloakRadiusInCells}}.
+
This flag determines whether or not a [[BuildingType]] can detect and reveal [[Cloakable|cloaked]] and [[subterranean]] units within a radius in cells specified by {{f|CloakRadiusInCells|link}}.
  
 
When a cloaked unit is detected for a player, an [[EVA Event]] will trigger and ''[[tibsun.mix]]''{{arr|r}}''speech01.mix''{{arr|r}}''00-i172.aud'' (''speech02.mix'' for [[Nod]]) will sound. The unit will then become visible and targetable until it is no longer within the detection range.
 
When a cloaked unit is detected for a player, an [[EVA Event]] will trigger and ''[[tibsun.mix]]''{{arr|r}}''speech01.mix''{{arr|r}}''00-i172.aud'' (''speech02.mix'' for [[Nod]]) will sound. The unit will then become visible and targetable until it is no longer within the detection range.

Revision as of 10:32, 27 November 2009

Tiberian Dawn The Covert Operations Red Alert Counterstrike Aftermath Tiberian Sun Firestorm HyperPatch Red Alert 2 Yuri's Revenge Ares Generals Zero Hour Tiberium Wars Kane's Wrath
Flag: SensorArray
File(s): rules(md).ini
Values: Boolean values: yes or no, true or false, 1 or 0
Default: false
Applicable to: BuildingTypes

Cc cnrdelete-all.pngLogic related to SensorArray, as a whole or in part, is obsolete in Red Alert 2 and/or Yuri's Revenge.



In Tiberian Sun

This flag determines whether or not a BuildingType can detect and reveal cloaked and subterranean units within a radius in cells specified by CloakRadiusInCells.

When a cloaked unit is detected for a player, an EVA Event will trigger and tibsun.mixspeech01.mix00-i172.aud (speech02.mix for Nod) will sound. The unit will then become visible and targetable until it is no longer within the detection range.

Similarly, when a subterranean unit is detected, an EVA Event will trigger and tibsun.mixspeech01.mix00-i174.aud (speech02.mix for Nod) will sound. The unit's selection box will be revealed until it is no longer within the detection range or it surfaces.

In Red Alert 2

Cc cnrdelete-all.png
Logic related to SensorArray, as a whole or in part, is obsolete in Red Alert 2 and Yuri's Revenge.

Although this flag is parsed, it no longer allows BuildingTypes to detect cloaked and subterranean units.